Muegge Products

Microwave generators

Microwave generators
  • Power-Supply

    Item number: MS030KE-514DE

    Frequency [MHz]
    915
    Output Power [W]
    30000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    -
    Line Voltage [V]
    400
    Mains voltage control circuit [V]
    -
    Line Frequency [Hz]
    50
    Cooling
    Air-water heat exchanger
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    No Front-Panel
    Interface
    A/D
    Interface 2
    -
    Interface 3
    -
    Interface 4
    -
    Interface 5
    -
    Width [mm (inch)]
    1056 (41,58)
    Height [mm (inch)]
    2261 (89,02)
    Depth [mm (inch)]
    605 (23,82)
    Protection
    IP55
    Isolator
    No
    Power-Supply
    Linear
  • Power-Supply

    Item number: MS050KE-511DE

    Frequency [MHz]
    915
    Output Power [W]
    50000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    -
    Line Voltage [V]
    400
    Mains voltage control circuit [V]
    -
    Line Frequency [Hz]
    50
    Cooling
    Air-water heat exchanger
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    No Front-Panel
    Interface
    A/D
    Interface 2
    Control panel
    Interface 3
    -
    Interface 4
    -
    Interface 5
    -
    Width [mm (inch)]
    800 (31,50)
    Height [mm (inch)]
    2250 (88,58)
    Depth [mm (inch)]
    1050 (41,34)
    Protection
    IP55
    Isolator
    No
    Power-Supply
    Linear
  • Power-Supply

    Item number: MS060KE-511DE

    Frequency [MHz]
    915
    Output Power [W]
    60000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    -
    Line Voltage [V]
    400
    Mains voltage control circuit [V]
    -
    Line Frequency [Hz]
    50 / 60
    Cooling
    Air-water heat exchanger
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    No Front-Panel
    Interface
    A/D
    Interface 2
    -
    Interface 3
    -
    Interface 4
    -
    Interface 5
    -
    Width [mm (inch)]
    1200 (47.24)
    Height [mm (inch)]
    2000 (78,74)
    Depth [mm (inch)]
    800 (31,5)
    Protection
    IP54
    Isolator
    No
    Power-Supply
    Linear
  • Power-Supply

    Item number: MS075KE-511DE

    Frequency [MHz]
    915
    Output Power [W]
    75000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    -
    Line Voltage [V]
    400
    Mains voltage control circuit [V]
    -
    Line Frequency [Hz]
    50
    Cooling
    Air-water heat exchanger
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    No Front-Panel
    Interface
    A/D
    Interface 2
    -
    Interface 3
    -
    Interface 4
    -
    Interface 5
    -
    Width [mm (inch)]
    1200 (47,24)
    Height [mm (inch)]
    2250 (88,58)
    Depth [mm (inch)]
    1050 (41,84)
    Protection
    IP54
    Isolator
    No
    Power-Supply
    Linear
  • Power-Supply

    Item number: MS075KE-512DL

    Frequency [MHz]
    915
    Output Power [W]
    75000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    -
    Line Voltage [V]
    400
    Mains voltage control circuit [V]
    -
    Line Frequency [Hz]
    50
    Cooling
    Air-water heat exchanger
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    No Front-Panel
    Interface
    Can-Bus
    Interface 2
    -
    Interface 3
    -
    Interface 4
    -
    Interface 5
    -
    Width [mm (inch)]
    1200 (47,24)
    Height [mm (inch)]
    2250 (88,58)
    Depth [mm (inch)]
    1050 (41,84)
    Protection
    IP40
    Isolator
    No
    Power-Supply
    Linear
  • Power-Supply

    Item number: MS100KE-511DE

    Frequency [MHz]
    915
    Output Power [W]
    100000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    -
    Line Voltage [V]
    480
    Mains voltage control circuit [V]
    -
    Line Frequency [Hz]
    50
    Cooling
    Air-water heat exchanger
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    No Front-Panel
    Interface
    A/D
    Interface 2
    Control panel
    Interface 3
    -
    Interface 4
    -
    Interface 5
    -
    Width [mm (inch)]
    1206 (47,48)
    Height [mm (inch)]
    2262 (89,06)
    Depth [mm (inch)]
    1108 (43,62)
    Protection
    IP54
    Isolator
    No
    Power-Supply
    Linear
  • Power-Supply

    Item number: MS100KE-512DE

    Frequency [MHz]
    915
    Output Power [W]
    100000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    -
    Line Voltage [V]
    400
    Mains voltage control circuit [V]
    -
    Line Frequency [Hz]
    50
    Cooling
    Air-water heat exchanger
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    -
    Interface
    A/D
    Interface 2
    -
    Interface 3
    -
    Interface 4
    -
    Interface 5
    -
    Width [mm (inch)]
    1206 (47,48)
    Height [mm (inch)]
    2262 (89,06)
    Depth [mm (inch)]
    1108 (43,62)
    Protection
    IP40
    Isolator
    No
    Power-Supply
    Linear
  • Power-Supply

    Item number: MX010KD-154KG

    Frequency [MHz]
    2450
    Output Power [W]
    10000
    Line connection
    3~ (L1 / L2 / L3 / PE)
    Control circuit connection [V]
    Line Voltage [V]
    400
    Mains voltage control circuit [V]
    Line Frequency [Hz]
    50 / 60
    Cooling
    Air / Water
    Pulse output power max [W]
    -
    Front-Panel (HMI)
    Operating Unit with Main Switch
    Interface
    front display
    Interface 2
    Can-Bus
    Interface 3
    A/D
    Interface 4
    RS-232
    Interface 5
    -
    Width [mm (inch)]
    484 (19,06)
    Height [mm (inch)]
    128 (5,04)
    Depth [mm (inch)]
    607 (23,90)
    Protection
    IP20
    Isolator
    No
    Related Magnetron Head
    MH010KS-250BF
    Power-Supply
    Switch-Mode

Microwave generators

Optimize your “”Cost of Ownership”” with proven microwave generators from MUEGGE for the frequency bands 915 MHz, 2450 MHz (2.45 GHz) or 5.8 GHz Our solutions are characterized by outstanding features in reliability, process speed and performance – ideal to minimize your downtimes.